Heat exchanger 2540C3001 (2040K 400V 50/60Hz ST C ASP) is a specialized component for cooling and excess heat dissipation systems in industrial, hydraulic, and process equipment. The model is built in the 2040K version, features an electrical execution of 400 V, and is designed to operate at a frequency of 50/60 Hz.
The product is used to maintain the required operating medium temperature and ensure stable equipment operation during extended duty cycles.
The exact part number 2540C3001 allows for correct model identification when selecting a replacement part, carrying out repairs, or performing scheduled maintenance.
Key Advantages
- exact part number 2540C3001 for identification;
- version 2040K;
- electrical execution 400 V;
- supply frequency 50/60 Hz;
- configuration ST C ASP;
- intended for cooling and heat dissipation systems;
- suitable for use in industrial and hydraulic systems;
- helps maintain a stable temperature profile;
- convenient selection for replacing matching components by full part marking.
Technical Specifications
| Parameter | Value |
| Product type | Heat exchanger |
| Part number | 2540C3001 |
| Model / version | 2040K |
| Supply voltage | 400 V |
| Frequency | 50/60 Hz |
| Additional marking | ST C ASP |
| Purpose | Dissipation and transfer of thermal energy |
| Field of application | Industrial, hydraulic, and process equipment |
Important Note Regarding Technical Parameters
The exact specifications of the specific execution 2540C3001 — thermal capacity, performance, medium flow rate, allowable operating pressure, temperature range, materials, overall and connection dimensions, fan parameters, wiring diagram, and other specifications — must be verified against the manufacturer’s technical documentation.
The designation 400 V 50/60 Hz defines the electrical execution of the product. Prior to electrical connection, verify the compliance of voltage, frequency, and wiring diagram with the specific equipment.
Operating Principle
The heat exchanger ensures the dissipation of excess thermal energy in accordance with the system design. Heat from the operating medium is transferred through the heat exchanging core and removed to the designated system circuit.
Maintaining the optimum operating medium temperature is critical for stable equipment operation, particularly under prolonged duty cycles and heavy service conditions.
Application Areas
The heat exchanger 2540C3001 can be used within:
- hydraulic systems;
- industrial machines and units;
- process equipment;
- cooling systems;
- hydraulic drives;
- systems with high thermal loads;
- equipment requiring reliable dissipation of excess heat.
Design Features of 2040K 400V 50/60Hz ST C ASP
Model 2540C3001 has a specific combination of parameters 2040K / 400V / 50/60Hz / ST C ASP. The complete designation must be taken into account when selecting a heat exchanger, as units within the same series may differ in electrical design, construction, overall dimensions, and port sizes.
The electrical execution 400 V 50/60 Hz is designed for the corresponding mains supply provided that the manufacturer’s requirements and the proper wiring diagram are observed.
Benefits of Use
A properly selected heat exchanger helps maintain the required operating temperature and ensures excess heat dissipation from the system.
Using a component that matches equipment parameters contributes to reliable operation and simplifies maintenance and servicing procedures.
The exact part number 2540C3001 facilitates locating the required replacement part and reduces the risk of an error when ordering.
Checklist Before Purchasing
Before ordering the heat exchanger, it is recommended to verify:
- Part number — 2540C3001.
- Full designation — 2040K 400V 50/60Hz ST C ASP.
- Supply voltage — 400 V.
- Frequency — 50/60 Hz.
- Overall and mounting dimensions.
- Port connection type and sizes.
- Operating medium.
- Allowable pressure and temperature.
- Required cooling system capacity.
- Compliance of the wiring diagram with equipment specifications.
Installation and Operating Guidelines
Heat exchanger installation must be performed in accordance with the manufacturer’s technical documentation and applicable safety standards.
Prior to installation, ensure the compatibility of the unit with the operating fluid, temperature, pressure, and other system parameters.
Electrical connections must be carried out only when the equipment is fully de-energized. Follow the manufacturer’s wiring diagram and verify mains supply conformity with 400 V 50/60 Hz parameters.
Following installation, it is recommended to inspect connections for leaks, ensure correct electrical wiring, and verify system operational stability under load.
Regular maintenance enables timely detection of contamination, damage, and other factors that could compromise heat dissipation efficiency.
Buy Heat Exchanger 2540C3001
Heat exchanger 2540C3001 (2040K 400V 50/60Hz ST C ASP) is a component for cooling and heat dissipation systems that can be utilized in industrial, hydraulic, and process equipment.
Before purchasing, it is recommended to match part number 2540C3001, version 2040K, electrical parameters 400V 50/60Hz, and marking ST C ASP with the equipment technical documentation.